Spectra Logic 10000 manual Library screens are locked, Library screen does not respond to touch

Models: 10000

1 136
Download 136 pages 25.74 Kb
Page 97
Image 97
Library screens are locked

Chapter 7. Troubleshooting

6.The fuses are visible through the fuse cutout in the library base plate. Replace the blown fuse with a fast-blow (standard) fuse.

D

 

 

 

ri

 

 

 

v

 

 

 

e

 

 

 

3 Sl

 

 

 

ot

D

 

 

 

r

 

 

 

i

 

 

 

v

 

 

 

e

 

 

 

4 Sl

 

 

 

o

 

 

 

t

 

Figure 7-4The fuses visible through the cutout in the base plate.

7.If necessary, re-install Drive 3.

i. Slide the drive back into its slot on the base plate.

5-volt fuse:

5V 8A-FB

12-volt fuse:

12V 2A-FB

12-volt analog fuse:

12V 8A-FB

ii.Tighten the screws that secure the drive to the base plate.

iii.Carefully reconnect the SCSI and power cables.

8.Replace the library cover.

9.Reconnect all of the library cables.

10.Reboot the library.

Library screens are locked

Screens may have been locked using the User or System Administrator password. See the administrator for the correct password.

Library screen does not respond to touch

You may have to power cycle the library to clear this error. Wait for the drive messages Loaded and/or Active to clear before cycling power. Once the library and drives are no longer active, power cycle the library and allow it to come ready. Retry the operation.