Chapter 6. Maintaining the Library

Replacing the Air Filter

Spectra 10000 libraries have a front panel with a removable air filter. Inspect these filters every three to four months and replace as necessary. If the filter is contaminated, replace it. A clogged air filter may cause operational errors due to excessive temperatures inside the library.

To order replacement filters, contact your sales representative.

Caution: Some environments may require more frequent filter inspection and replacement. If library filters get clogged quickly, you should consider moving the library to a more dust free location or improve the environment where it is located.

If air filters have excessive clogging due to neglect, it is recommended that the filter be replaced immediately. After replacing the filter, all tape drive heads should be cleaned. The inside of the library, including the tape cartridges, should also be cleaned with a low-pressure vacuum.

To check and replace the filter:

1.Insert a plastic card into the front panel release on the left side of the faceplate’s slotted grill (Figure 6-4).

Figure 6-4The front panel release.