Tutorials
2-74 AWG610 Arbitrary Waveform Generator User Manual
7. Repeat steps 2 through 6 to insert lines 2 through 4 and enter waveform file
names listed in Table 2–18 into the CH1 column.
8. Repeatedly push the y button to go back to line 1.
9. Push the ' button to place the highlighted cursor on the Repeat Count
column.
The side menu automatically changes and the Repeat Count side menu item
appears. Note that the Repeat Count side menu item is selected by default.
10. Push the 4, 0, 0, 0, 0, and ENTER buttons in this order.
The repeat count 40000 is set in the Repeat Count column.
11. Push the b button once to move the highlighted cursor to the next line.
12. Repeat step 10 to enter the repeat count for lines 2 through 4 as specified in
Table 2–18.
You have finished editing the sequence table. The table should look like
Figure 2–45.
Figure 2-45: Example of sequence(SUBSEQ.SEQ)