3 Tests and Diagnostics | 3.3 Setting of the hardware configuration |
?Setting of the HWSC
?Setting of the UUID
?Display of the DMI information (including UUID)
?Setting of DVD region code (Yes/No)
After completion of the above settings, H/W configuration & DMI information are appeared in order. Check the contents and press Enter.
Subtest 02 | Region write |
|
|
| This subtest executes the setting of the region code for DVD drive based on the | ||
| destination of the machine. |
| |
| When the region code is already written, test ends without setting. | ||
| The following message appears in the display after setting the region code. | ||
| Press any key to return to the H/W initial information setting tool menu. | ||
| *********************************** | ||
| ******* | It completed | ******* |
***********************************
* | * |
Press any key to continue... |
|
Subtest 03 DMI information save
This is one of tools to copy the DMI information to a new PCB after replacing.
This subtest saves all the DMI data in a floppy disk.
Subtest 04 DMI information recovery
This is one of tools to copy the DMI information to a new PCB after replacing.
This subtest writes all the DMI data in the floppy disk into the new PCB.
Note: Since the data of UUID is updated every time when this subtest, DMI information recovery, is done, the saved UUID data is not written.
PORTEGE A200 Maintenance Manual |