2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting |
?DC power supply (AC adapter)
Error code | Meaning |
|
|
10h | AC Adapter output voltage is over 16.5V. |
|
|
11h | Commondock output voltage is over 16.5V. |
|
|
12h | Current from the DC power supply is over 6.05A. |
|
|
13h | Current from the DC power supply is over 0.5A when there is no load. |
|
|
14h | Abnormal current has been sensed 0[A]. |
|
|
?Main battery
Error code | Meaning |
|
|
21h | Main battery charge current is over 6.05A. |
|
|
22h | Main battery discharge current is over 0.5A when there is no load. |
|
|
23h | Main battery charge current is over 3.1A when AC adapter is not |
| connected. |
|
|
24h | Abnormal current has been sensed 0[A]. |
|
|
25h | Main battery charge current is over 0.3A. |
|
|
? S3V output
Error code | Meaning |
|
|
40h | S3V voltage is 3.14V or less when the computer is powered on/off. |
|
|
45h | S3V voltage is 3.14V or less at |
|
|
? 1R5-C1V output
Error code |
| Meaning |
|
|
|
50h | 1R5 | |
|
|
|
51h | 1R5 | |
|
|
|
52h | 1R5 | |
|
|
|
53h | 1R5 | |
|
|
|
54h | 1R5 | |
|
|
|
55h | 1R5 | |
| (CV support) | |
|
|
|
PORTEGE A200 Maintenance Manual (960 |