2.3 Power Supply Troubleshooting

2 Troubleshooting Procedures

? 1R25-P1V output

Error code

Meaning

 

 

D0h

1R25-P1V voltage is over 1.50V when the computer is powered on/off.

 

 

D1h

1R25-P1V voltage is 1.063V or less when the computer is powered on.

 

 

D2h

1R25-P1V voltage is 1.063V or less at power-on.

 

 

D3h

1R25-P1V voltage is 1.063V or more when the computer is powered

 

off.

 

 

D4h

1R25-P1V voltage is 1.063V or less while the computer is suspended.

 

 

? 2R5-B2V output

Error code

 

Meaning

 

 

 

E0h

2R5

-B2V voltage is over 3.00V when the computer is powered on/off.

 

 

 

E1h

2R5

-B2V voltage is 2.125V or less when the computer is powered on.

 

 

 

E2h

2R5

-B2V voltage is 2.125V or less at power-on.

 

 

 

E3h

2R5

-B2V voltage is 2.125V or more when the computer is powered off.

 

 

 

E4h

2R5

-B2V voltage is 2.125V or less while the computer is suspended.

 

 

 

Check 2 In the case of error code 10h or 12h:

?Make sure the AC adapter and AC power cord are firmly plugged into the DC IN 15 V socket and wall outlet. If the cables are connected correctly, go to the following step:

?Connect a new AC adapter and AC power cord. If the error still exists, go to Procedure 5.

Check 3 In the case of error code 2Xh:

?Go to Procedure 3.

Check 4 For any other errors, go to Procedure 5.

PORTEGE A200 Maintenance Manual (960 -499)