4 Replacement Procedures

4.26 Fluorescent lamp

4.26 Fluorescent lamp

This system uses LCD modules from the following suppliers. The procedure for replacing the fluorescent lamp assembly (hereafter refer to fluorescent lamp) is different for each LCD module. Refer to the appropriate procedure.

Type

Part.No

 

Supplier

Section

 

 

 

 

 

12.1 inch

G33C0000J210

TMD

 

4.26.1

 

 

 

 

 

Note: 1.When working with a LCD module, always use a flat, grounded table.

2.Handle the backlight unit in the environment without dust, such as on the clean bench. Keep the worktable free from any screws or other material that may scratch the LCD surface.

3.Use an anti-static or protective sheet.

4.When replacing the FL unit, cover with a finger protector or similar to prevent dirtying or scratching the LCD panel.

5.Take care when handling the lamp. Excessive force may break the lamp.

6.Take care not to dirty or deform the lamp reflector.

7.Ensure always that the power of the LCD module is turned off before connecting or disconnecting cables and connectors.

4-60

PORTEGE A200 Maintenance Manual (960 -499)

Page 265
Image 265
Toshiba A200 manual Replacement Procedures Fluorescent lamp, Type Part.No Supplier Section Inch G33C0000J210, 26.1