<In case of SP80>

Check

Outdoor

 

 

 

Check and troubleshooting

code

LED display

 

 

(Item without special mention Indicates part of outdoor unit.)

 

 

 

 

 

 

 

 

 

[P03]

<Display 1>

<Display 2>

[Discharge temp. error]

 

 

 

 

 

 

¡

¥

 

 

 

 

 

 

 

 

 

 

 

 

¡

¥

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

Is there gas leak?

 

Repair defective position.

 

 

 

¡

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there refrigerant shortage?

 

 

Recharge refrigerant.

 

 

 

l

l

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

¡

l

 

 

 

 

 

NO

 

 

 

 

 

¡

¡

 

Is PMV under correct conditions?

 

Repair defective position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace defective part.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does an abnormal overload happen?

 

Remove and improve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the cause of overload.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is connection of CN603 correct?

 

Correct connector.

 

 

 

 

 

Is resistance value of TD sensor correct?

 

 

Sensor error Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

Defect Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[P04]

 

 

There is a possibility that it is one of the following errors.

 

 

 

Confirm LED on outdoor P.C. board to judge which error it is.

 

 

 

Power supply error (Vdc), High pressure protective operation, Case thermostat

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

<Display 1>

<Display 2>

[Case thermostat operation] Refer to [H04] column.

 

l

l

 

 

 

 

 

 

 

 

 

 

 

 

l

l

 

 

 

 

 

 

 

 

 

 

 

 

¡

¥

 

 

 

 

 

 

 

 

 

 

 

 

l

l

 

 

 

 

 

 

 

 

 

 

 

 

¡

l

 

 

 

 

 

 

 

 

 

 

 

 

¡

¡

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Display 1>

<Display 2>

[Power supply error] Refer to [P05] column.

 

 

 

 

 

¡

¥

 

 

 

 

 

 

 

 

 

 

 

 

¡

l

 

 

 

 

 

 

 

 

 

 

 

 

¡

¥

 

 

 

 

 

 

 

 

 

 

 

 

l

l

 

 

 

 

 

 

 

 

 

 

 

 

¡

l

 

 

 

 

 

 

 

 

 

 

 

 

¡

¡

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Display 1>

<Display 2>

[High pressure protective operation]

Refer to [P20] column.

¡l

¡l

¡¥

l l

¡¥

¡¡

[P05] <Display 1> <Display 2> [Power supply error]

¡¥

¡

l

 

Is AC mains voltage correct?

NO

 

 

 

 

 

 

 

Confirm power supply

 

¡

¥

 

 

 

 

 

198 to 264V

 

 

construction, etc.

 

l

l

 

 

 

 

 

YES

 

 

 

 

 

 

 

¡

l

 

 

 

 

 

 

 

 

¡

¡

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defect Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 101 –

Page 101
Image 101
Toshiba RAV-SP564ATZ-E 101, P05 Display 1 Display 2 Power supply error, Repair defective position Replace defective part