<In case of SP40 to 56>

Check

APPLICATION CONTROL KIT

 

Check / Countermeasures

code

 

LED display

 

(Part without special mention indicates a part of the outdoor unit.)

 

 

 

 

 

 

[H03]

D01

D02

D03

D04

[Power supply error, Current detection circuit error]

 

(Red)

(Yellow) (Yellow) (Yellow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¥

¥

l

l

Are connections of wires correct?

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

Between power cable and terminal block

 

 

 

 

Correct wires

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Between outdoor P.C. board and terminal block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defect Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[L29]

D01

D02

D03

D04

[Power supply error, Current detection circuit error]

 

(Red)

(Yellow) (Yellow) (Yellow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¡

l

l

¡

Is AC mains voltage correct?

 

NO

 

 

 

 

Correct

 

 

 

l

 

or

l

198 to 264V

 

 

 

 

 

power supply line.

 

 

 

 

 

 

 

 

 

 

 

 

¥

¥

YES

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor trouble

 

 

 

 

 

 

 

Is compressor under correct conditions?

 

 

 

 

 

Rare short check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

Defective Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defect Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[P03]

D01

D02

D03

D04

[Discharge temp. error]

 

 

 

 

 

 

 

 

 

 

 

 

(Red)

(Yellow) (Yellow) (Yellow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l

¡

¡

l

Is there gas leak?

YES

 

Repair defective position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there refrigerant shortage?

 

 

 

 

 

Recharge refrigerant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is PMV under correct conditions?

 

 

Repair defective position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace defective part.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does an abnormal overload happen?

 

Remove and improve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the cause of overload.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is connection of CN601 correct?

 

 

Correct connector.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is resistance value of TD sensor correct?

 

 

 

 

 

Sensor error Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defect Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[P04]

D01

D02

D03

D04

[Power supply error (Voltage error)]

 

 

 

 

 

 

 

 

 

 

 

 

(Red)

(Yellow) (Yellow) (Yellow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¡

l

l

¡

Is AC mains voltage correct?

 

NO

 

Confirm power supply

 

 

 

 

 

 

 

198 to 264V

 

 

 

 

 

construction, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defect Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[P05]

D01

D02

D03

D04

[Power supply error (Voltage error)]

 

 

 

 

 

 

 

 

 

 

 

 

(Red)

(Yellow) (Yellow) (Yellow)

Refer to columns [H03] and [P04] and then check power supply and

 

¥

¥

l

l

voltage error.

 

 

 

 

 

 

 

 

 

 

 

or

¡ l l ¡

LED display legend: l Go off, ¡ Go on, ¥ Flash (5Hz)

– 93 –

Page 93
Image 93
Toshiba RAV-SP404AT-E Power supply error, Current detection circuit error, L29, P03, Discharge temp. error, P04, P05