<In case of SP80>

10-2-6. Diagnostic Procedure for Each Check Code (Outdoor Unit)

1)This section describes the diagnostic method for each check code displayed on the wired remote controller.

2)In some cases, a check code indicates multiple symptoms.

In this case, confirm LED display on the outdoor P.C. board to narrow the contents to be confirmed.

3)The check code on the remote controller is displayed only when the same error occurred continuously by multiple times while LED of the outdoor P.C. board displays even an error which occurred once. Therefore the display on the remote controller may differ from that of LED.

How to check LED display on outdoor P.C. board

Dip switch setup

When turning on 1) only of SW803, the latest error is displayed. As the memory is stored, it can be confirmed even if the power supply is turned off once. (excluding outside temp. sensor (TO) error)

When the work finished or the outdoor temp. sensor (TO) error was found, turn off all of SW803. (The error which occurs at present is displayed.)

<Latest error display>

Only 1) of SW803 is ON.

 

 

4

 

 

 

 

 

 

3

ON

 

 

2

 

 

1

 

 

 

 

 

<Error display, which occurs at present>

All SW803 are OFF. (Initial status)

 

 

4

 

 

 

 

 

 

3

ON

 

 

2

 

 

1

 

 

 

 

 

Display selection

When an error happens, some of yellow LED (D800 to D804) turn on. <Display 1>

If pushing the button switch SW800 for 1 second under the above condition, the yellow LED is displayed with flashing. <Display 2>

When pushing SW800 for 1 second again, the status returns to <Display 1>.

The error contents can be confirmed by combining <Display 1> and <Display 2>.

D800 (Yellow)

D801 (Yellow)

D802 (Yellow)

D803 (Yellow)

D804 (Yellow)

D805 (Green)

<Display 1> ó<Display 2>

(No error) (Error occurred)

(Push SW800)

l

¡

l

l

¡

l

l

l

¥

l

l

l

l

¡

l

¡

¡

¡

(Example of discharge temp. sensor error)

l: Go off, ¡ : Go on, ¥ : Flash

Check

Outdoor

 

 

Check and troubleshooting

 

 

 

code

LED display

(Item without special mention Indicates part of outdoor unit.)

 

 

 

 

 

 

 

 

 

 

 

 

[E04]

[Indoor/Outdoor communication error]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is setting of group address

NO

 

 

 

 

 

 

 

 

Check Item code [14].

 

 

 

 

 

 

 

 

 

 

of remote controller correct?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are inner wiring of indoor unit and

NO

 

 

 

 

 

 

 

 

Correct wiring

 

 

 

 

 

 

 

 

 

 

inter-unit wires (1, 2, 3) correct?

 

 

and inter-unit cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are CN04 connection and wiring

NO

 

 

 

 

 

 

 

 

Correct wiring of connectors

 

 

 

 

 

 

 

 

 

 

of terminal blocks (1, 2, 3) correct?

 

 

and terminal blocks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After turning off the power supply,

NO

 

 

 

 

 

 

 

 

Check indoor P.C. board.

 

 

 

 

turn on it again.

 

 

 

 

 

 

 

 

Defect

Replace

 

 

 

 

 

 

 

 

 

 

Does D502 (Orange LED) flash?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check outdoor P.C. board.

 

 

 

 

 

 

 

 

 

Defect

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 