ZyXEL Communications 792H manual Internal Sptgen FTP Download Example

Models: 792H

1 428
Download 428 pages 12.67 Kb
Page 409
Image 409

Prestige 792H G.SHDSL Router

field value is not legal error:-1

ROM-t is not saved, error Line ID:10000000 reboot to get the original configuration Bootbase Version: V2.02 2/22/2001 13:33:11 RAM: Size = 8192 Kbytes

FLASH: Intel 8M *2

Figure 38-2 Invalid Parameter Entered: Command Line Example

The Prestige will display the following if you enter parameter(s) that are valid.

Please wait for the system to write SPT text file(ROM-t)...

Bootbase Version: V2.02 2/22/2001 13:33:11

RAM: Size = 8192 Kbytes

FLASH: Intel 8M *2

Figure 38-3 Valid Parameter Entered: Command Line Example

38.3 Internal SPTGEN FTP Download Example

1.Launch your FTP application.

2.Enter "bin".

The command “bin” sets the transfer mode to binary.

3. Get "rom-t" file.

The command “get” transfers files from the Prestige to your computer. The name “rom-t” is the configuration filename on the Prestige.

c:\ftp 192.168.1.1

220 PPP FTP version 1.0 ready at Sat Jan 1 03:22:12 2000

User (192.168.1.1:(none)):

331 Enter PASS command Password:

230 Logged in ftp>bin

200 Type I OK ftp> get rom-t ftp>bye c:\edit rom-t

(edit the rom-t text file by a text editor and save it)

4. Edit the "rom-t" file using a text editor (do not use a word processor). You must leave this FTP screen to edit.

Figure 38-4 Internal SPTGEN FTP Download Example

Internal SPTGEN

38-3

Page 409
Image 409
ZyXEL Communications 792H manual Internal Sptgen FTP Download Example, Invalid Parameter Entered Command Line Example