Chapter 31 ADP

31.3.1 Base Profiles

The ZyWALL comes with base profiles. You use base profiles to create new profiles. In the Configuration > Anti-X > ADP > Profile screen, click Add to display the following screen.

Figure 304 Base Profiles

These are the default base profiles at the time of writing.

Table 154

Base Profiles

BASE

 

DESCRIPTION

PROFILE

 

 

 

none

 

All traffic anomaly and protocol anomaly rules are disabled. No logs are

 

 

generated nor actions are taken.

 

 

 

all

 

All traffic anomaly and protocol anomaly rules are enabled. Rules with a

 

 

high or severe severity level (greater than three) generate log alerts

 

 

and cause packets that trigger them to be dropped. Rules with a very

 

 

low, low or medium severity level (less than or equal to three) generate

 

 

logs (not log alerts) and no action is taken on packets that trigger them.

 

 

 

OK

 

Click OK to save your changes.

 

 

 

Cancel

 

Click Cancel to exit this screen without saving your changes.

 

 

 

31.3.2 Configuring The ADP Profile Summary Screen

Select Configuration > Anti-X > ADP > Profile.

Figure 305 Configuration > Anti-X > ADP > Profile

 

517