Chapter 35 User/Group

35.4.2 User Aware Login Example

Access users cannot use the Web Configurator to browse the configuration of the ZyWALL. Instead, after access users log into the ZyWALL, the following screen appears.

Figure 340 Web Configurator for Non-Admin Users

The following table describes the labels in this screen.

Table 177 Web Configurator for Non-Admin Users

LABEL

DESCRIPTION

User-defined

Access users can specify a lease time shorter than or equal to the one

lease time

that you specified. The default value is the lease time that you specified.

(max ...

 

minutes)

 

 

 

Renew

Access users can click this button to reset the lease time, the amount of

 

time remaining before the ZyWALL automatically logs them out. The

 

ZyWALL sets this amount of time according to the

 

User-defined lease time field in this screen

 

Lease time field in the User Add/Edit screen (see Section 35.2.1

 

on page 586)

 

Lease time field in the Setting screen (see Section 35.4 on page

 

591)

 

 

Updating lease

This box appears if you checked the Allow renewing lease time

time

automatically box in the Setting screen. (See Section 35.4 on page

automatically

591.) Access users can select this check box to reset the lease time

 

automatically 30 seconds before it expires. Otherwise, access users have

 

to click the Renew button to reset the lease time.

 

 

Remaining

This field displays the amount of lease time that remains, though the

time before

user might be able to reset it.

lease timeout

 

 

 

Remaining

This field displays the amount of time that remains before the ZyWALL

time before

automatically logs the access user out, regardless of the lease time.

auth. timeout

 

 

 

596

 