Chapter 31 ADP

The following table describes the fields in this screen.

Table 156 Configuration > ADP > Profile > Traffic Anomaly

LABEL

DESCRIPTION

Name

This is the name of the ADP profile. You may use 1-31 alphanumeric

 

characters, underscores(_), or dashes (-), but the first character cannot

 

be a number. This value is case-sensitive. These are valid, unique profile

 

names:

 

MyProfile

 

mYProfile

 

Mymy12_3-4

 

These are invalid profile names:

 

1mYProfile

 

My Profile

 

MyProfile?

 

Whatalongprofilename123456789012

 

 

Scan/Flood

 

Detection

 

 

 

Sensitivity

(Scan detection only.) Select a sensitivity level so as to reduce false

 

positives in your network. If you choose low sensitivity, then scan

 

thresholds and sample times are set low, so you will have fewer logs and

 

false positives; however some traffic anomaly attacks may not be

 

detected.

 

If you choose high sensitivity, then scan thresholds and sample times are

 

set high, so most traffic anomaly attacks will be detected; however you

 

will have more logs and false positives.

 

 

Block

Specify for how many seconds the ZyWALL blocks all packets from being

Period

sent to the victim (destination) of a detected anomaly attack.

 

 

Activate

To turn on an entry, select it and click Activate.

 

 

Inactivate

To turn off an entry, select it and click Inactivate.

 

 

Log

To edit an item’s log option, select it and use the Log icon. Select

 

whether to have the ZyWALL generate a log (log), log and alert (log

 

alert) or neither (no) when traffic matches this anomaly rule. See

 

Chapter 46 on page 723 for more on logs.

 

 

Action

To edit what action the ZyWALL takes when a packet matches a rule,

 

select the signature and use the Action icon.

 

none: The ZyWALL takes no action when a packet matches the

 

signature(s).

 

block: The ZyWALL silently drops packets that matches the rule. Neither

 

sender nor receiver are notified.

 

 

#

This is the entry’s index number in the list.

 

 

Status

The activate (light bulb) icon is lit when the entry is active and dimmed

 

when the entry is inactive.

 

 

520

 