230CHAPTER 8: FIBER DISTRIBUTED DATA INTERFACE (FDDI)

fddi path tvxLowerBound

3500

9000

9400

3900

9300

Specifies the minimum time value (in microseconds) of fddiMAC tvxValue that any MAC that is configured in this path uses.

Valid Minimum Abbreviation

fd pa tv

Important Considerations

A MAC uses its valid transmission timer (TVX) to detect and recover from certain ring errors. If a valid frame has not passed through a MAC during the time indicated by fddiMACTvxValue, the MAC reinitializes the ring.

By adjusting the tvxLowerBound value, you specify how quickly the ring recovers from an error. The lower you set this value, the faster the network reacts to problems, but the ring might be reinitialized when there is no problem.

The higher you set this value, the less chance of frequent reinitializations, but the network takes longer to recover from errors.

You can use this command to configure the same setting on multiple ports simultaneously. When you specify multiple port numbers, the system prompts you to choose the setting and then applies it to all of the ports.

Options

Prompt

Description

Possible Values

[Default]

 

 

 

 

Ports

One or more FDDI station ports

Any of the

 

for which you want to set the

available

 

 

tvxLowerBound

ports on the

 

 

 

installed FDDI

 

 

 

modules

 

Path

Path that you want to set:

 

A DAS port has primary and

 

 

secondary paths.

 

A SAS port has only a

 

 

primary path.

all

p (primary)

s (secondary)

all

tvxLowerBound Minimum time value of

0 – 4294967295 2500

fddiMAC tvxValue that any

microseconds

MAC that is configured onto

 

this path uses

 

 

 

Page 230
Image 230
3Com 3500 manual Fddi path tvxLowerBound