fddi path tmaxLowerBound 231
fddi path
3500
9000
9400
3900
9300
tmaxLowerBound
Specifies the minimum time value (in microseconds) of fddiMAC T-Max
that any MAC that is configured in this path uses. This value specifies the
boundary for how high T-Req (the requested token rotation time) can be
set.
Valid Minimum Abbreviation
fd pa tm
Important Consideration
You can use this command to configure the same setting on m ultiple
ports simultaneously. When you specify multiple port numbers, the
system prompts you to choose the setting and then applies it to all of
the ports.
Options
Prompt Description Possible Values [Default]
Ports One or more FDDI station
ports for which you want to
set the tmaxLower Bound
Any of the
available
ports on the
installed FDDI
modules
all
Path Path that you want to set.
A DAS port has primary
and secondary paths.
A SAS port has only a
primary path.
p (primary)
s (secondary)
all
tmaxLowerBound Minimum time value of
fddiMAC T-Max that any
MAC that is configured onto
this path uses
0 – 4294967295
microseconds
16500