bridge addressThreshold

3500

9000

9400

3900

9300

bridge addressThreshold 257

For CoreBuilder 9000: Applies to Layer 3 switching modules only.

Sets the reporting threshold for the number of Ethernet addresses that are known. When this threshold is reached, the system generates the SNMP trap called addressThresholdEvent.

Valid Minimum Abbreviation

b ad

Important Considerations

The bridge address table size on CoreBuilder switches is 32K; that is, the bridge can store a maximum of 32768 addresses.

The range of valid values for this parameter is between 1 and 1 plus the address table size. Setting the address threshold to the highest possible value prevents the system from generating the trap, because the value can never be reached.

Options

Prompt

Description

Possible Values

[Default]

 

 

 

 

address

Threshold for the total number

1 – 32769

29491 (factory

threshold

of addresses that are known

 

default), or

 

on this bridge

 

current value

 

 

 

 

Page 257
Image 257
3Com 3500 manual Bridge addressThreshold