qos classifier define 695

Options

Prompt

Description

Possible Values

[Default]

Classifier

Number of the flow

number

or nonflow classifier

 

in the range of

 

1 – 498

Flow classifiers: 1 – 399 –

(except 20 and 23, which are predefined flow classifiers)

Nonflow classifiers:

400 – 498, (except

401 – 407, 420, 430, 440, 450, 460, 470, 480, and 490. 401 – 407 are predefined nonflow classifiers with applied controls and IEEE 802.1p tag values of 1 – 7.)

Classifier name Name that you assign to the classifier

Cast type

Cast type for the

 

flow or nonflow

 

classifier

Protocol type

IP or other protocol

 

type, if applicable,

 

that you want to

 

associate with the

 

flow or nonflow

 

classifier

Source IP

For flow classifiers

address

only, IP address of

 

the source

Unique name with up to – 32 characters (Use " around any string with embedded spaces. Use

"" to enter an empty string.)

? (for a list of selection criteria)

Flow classifiers: unicast, – multicast, or all

Nonflow classifiers: unicast, multicast, broadcast, or all

? (for a list of selectable cast types)

Flow classifiers: IP

protocol type with TCP,

 

UDP, or all

 

Nonflow classifiers: TCP, IP, IPX, AppleTalk, custom, or any

? (for a list of selectable protocol types)

Up to 255.255.255.255

0.0.0.0

 

(factory

 

default,

 

wildcard

 

match)

Page 695
Image 695