SwitchBlade x8106 Chassis Switch Installation Guide

Installing the AT-SBxPWRSYS1 DC Power Supply

This section contains the installation procedure for the AT-SBxPWRSYS1

DC Power Supply. For background information, refer to “AT-

SBxPWRSYS1 DC Power Supply” on page 57.

Caution

The electronic components in the AT-SBxPWRSYS1 DC Power Supply can be damaged by electro-static discharges (ESD). Follow the procedure in “Protecting Against Electrostatic Discharge (ESD)” on page 90 to guard against ESD damage when unpacking and installing the power supply.

To install the power supply, perform the following procedure:

1.Choose a slot in the chassis for the AT-AT-SBxPWRSYS1 DC System Power Supply.

You may install it in slot C or D, shown in Figure 46 on page 91. The first AT-SBxPWRSYS1 Power Supply should be installed in slot D, because the slot does not have a blank power supply panel.

Caution

The AT-SBxPWRSYS1 DC Power Supply will not work in slot A or B.

2.If the chassis already has a power supply in slot D, remove the blank power supply panel from slot C by lifting the blank panel handle and sliding it out of the slot, as shown in Figure 59 on page 104.

103

Page 103
Image 103
Allied Telesis X8106 manual Installing the AT-SBxPWRSYS1 DC Power Supply