A-156 682XXB/683XXB MM
TEST MODEL
RECORD 68269B/68369B
3-10 Single Sideband Phase Noise Test
Test Procedure Measured Value Upper Limit
SetF1 to 0.6 GHz
Recordthe phase noise levels at these offsets:
100Hz ...............................
1kHz ..............................
10kHz ..............................
100kHz ..............................
_______________dBc
_______________dBc
_______________dBc
_______________dBc
–74dBc
–85dBc
–82dBc
–97dBc
SetF1 to 2.0 GHz
Recordthe phase noise levels at these offsets:
100Hz ...............................
1kHz ..............................
10kHz ..............................
100kHz ..............................
_______________dBc
_______________dBc
_______________dBc
_______________dBc
–77dBc
–85dBc
–83dBc
–99dBc
3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz (Continued)
Test Procedure (11 to 20 GHz) Measure Value Upper Limit
SetF1 to 12.4 GHz
Recordthe level of all harmonics of the 12.4 GHz carrier:
24.8GHz (2nd harmonic) .....................
37.2GHz (3rd harmonic) ......................
_______________dBc
_______________dBc
–60dBc*
–60dBc*
SetF1 to 16.0 GHz
Recordthe level of all harmonics of the 16.0 GHz carrier:
32.0GHz (2nd harmonic) ..................... _______________dBc –60dBc*
SetF1 to 20.0 GHz
Recordthe level of all harmonics of the 20.0 GHz carrier:
40.0GHz (2nd harmonic) ..................... _______________dBc –60dBc*
*–50 dBc if Option 15B (High Power) installed.