Control Byte

Name

Description

Watchdog

 

#

Timer

 

 

 

 

 

 

 

 

106

(6Ah)

Set Spectrum Analyzer

Sets the Spectrum Analyzer resolution BW frequency (obsolete)

Yes

Resolution Bandwidth Freq

 

 

 

 

 

 

 

 

 

107

(6Bh)

Set Spectrum Analyzer

Sets the Spectrum Analyzer video BW frequency (obsolete)

Yes

Video Bandwidth Freq

 

 

 

 

 

 

 

 

 

108

(6Ch)

Set Spectrum Analyzer

Sets the Spectrum Analyzer sweep mode

Yes

Sweep Mode

 

 

 

 

 

 

 

 

 

109

(6Dh)

Set Spectrum Analyzer

Sets specified marker to peak value of the sweep

Yes

Marker to Peak

 

 

 

 

 

 

 

 

 

110

(6Eh)

Set Spectrum Analyzer

Sets the center frequency equal to the frequency of the specified marker

Yes

Marker to Center

 

 

 

 

 

 

 

 

 

111

(6Fh)

Set Spectrum Analyzer

Sets the attenuation for the Site Master Spectrum Analyzer mode (obsolete)

Yes

Attenuation

 

 

 

 

 

 

 

 

 

112

(70h)

Set VNA Segmented Limit

Sets the position and On/Off status of the segmented limit lines for the VNA

Yes

Lines

modes

 

 

 

 

 

 

 

 

113

(71h)

Set Spectrum Analyzer

Sets the position and On/Off Status of a limit segment for the SPA mode

Yes

Multiple Limit

 

 

 

 

 

 

 

 

 

114

(72h)

Set Return Spectrum

If this is enabled, the duration of the current sweep (in milliseconds) will be

Yes

Analyzer Sweep Time

returned as 4 bytes via the serial port at the end of the sweep

 

 

 

 

 

 

 

 

115

(73h)

Set Reference Level Offset

Sets the value of the reference level offset

Yes

 

 

 

 

 

117

(0x75)

Read Marker Value

Returns the frequency location of the specified marker, and the value at that

Yes

location

 

 

 

 

 

 

 

 

 

118

(76h

Set Sweep Averaging

Sets the number of sweeps to average

Yes

 

 

 

 

 

120

(78h)

Field InstaCal

Initiates an InstaCal calibration

—-

 

 

 

 

 

124

(7Ch)

Read InstaCal Module

Returns the InstaCal Module serial number in ASCII

Yes

ASCII Serial Number

 

 

 

 

 

 

 

 

 

129

(81h)

Set Site Master Marker

Sets an individual marker in current measurement mode to either peak

Yes

(Peak/Valley)

(maximum) signal or valley (minimum) signal

 

 

 

 

 

 

 

 

133

(85h)

Set/Reset SPA External

Sets the external reference frequency for the spectrum analyzer

Yes

Reference

 

 

 

 

 

 

 

 

 

134

(86h)

Check External SPA

Returns the state of the SPA external reference

—-

Reference

 

 

 

 

 

 

 

 

 

136

(88h)

Set SPA Preamp State

Sets the state of the SPA preamp

Yes

 

 

 

 

 

140

(8Ch)

Set SPA Units

Sets the scale type (logarithmic or linear) and the units

Yes

 

 

 

 

 

141

(8Dh)

Set SPA Resolution

Sets the resolution BW frequency for the Spectrum Analyzer

Yes

Bandwidth

 

 

 

 

 

 

 

 

 

142

(8Eh)

Set SPA Video Bandwidth

Sets the video BW frequency for the Spectrum Analyzer

Yes

 

 

 

 

 

143

(8Fh)

Set SPA Attenuation

Sets the attenuation for the Spectrum Analyzer

Yes

 

 

 

 

 

145

(91h)

Set AM/FM Demod

Sets the AM/FM/SSB Demodulation state

Yes

 

 

 

 

 

197

(C5h)

Set Baud Rate

Sets the serial communication baud rate for this session

Yes

 

 

 

 

 

198

(C6h)

Set Language

Sets the Site Master display language

Yes

 

 

 

 

 

208

(D0h)

Query Time

Queries the Site Master for the current time in ASCII format

—-

 

 

 

 

 

221

(DDh)

Read Main Serial Number

Returns the Main (External) Serial Number as four bytes

Yes

 

 

 

 

 

255

(FFh)

Exit Remote Mode

Ends serial communications

—-

 

 

 

 

A001h

Set T1 Transmission Level

Sets the transmission level of T1 measurement mode

Yes

 

 

 

 

A002h

Set T1/E1 Clock Source

Sets the Clock Source of T1/E1 measurement mode

Yes

 

 

 

 

A003h

Set T1/E1 Pattern

Sets the data pattern of T1/E1 measurement mode

Yes

 

 

 

 

 

Site Master PM

5

Page 11
Image 11
Anritsu S332D, S331D manual 78h Field InstaCal Initiates an InstaCal calibration