Anritsu S331D, S332D manual Site Master PM

Models: S332D S331D

1 132
Download 132 pages 8.91 Kb
Page 12
Image 12

Control Byte

Name

Description

Watchdog

#

Timer

 

 

 

 

 

 

A004h

Set T1/E1 Error Insert

Sets the Insertion Error type and the number of errors

Yes

Type/Value

 

 

 

 

 

 

 

A005h

Set T1/E1 Framing Mode

Sets the Framing Mode of T1/E1 measurement

Yes

 

 

 

 

A006h

Start and Stop T1/E1

Toggles state of T1 and E1 measurements

—-

Measurement

 

 

 

 

 

 

 

A007h

Insert Error for T1/E1

Inserts the error defined into the data flow

—-

Measurement

 

 

 

 

 

 

 

A008h

Get T1/E1 Pattern

Returns the current pattern for T1 and E1 modes

—-

 

 

 

 

A009h

Get T1/E1 Frame Sync

Returns the current frame sync status for T1 and E1 modes

—-

Status

 

 

 

 

 

 

 

A00Ah

Get T1/E1 Pattern Sync

Returns the current pattern sync status for T1 and E1 modes

—-

Status

 

 

 

 

 

 

 

A00Bh

Get T1/E1 Carrier Status

Returns the carrier status for T1 and E1 modes

—-

 

 

 

 

A00Ch

Get T1/E1 Error Type and

Returns the error type and numbers for T1 and E1 modes

—-

Number

 

 

 

 

 

 

 

A00Dh

Set T1/E1 Line Coding

Sets line coding options for T1 and E1 modes

Yes

Options

 

 

 

 

 

 

 

A00Eh

Set E1 Impedance Options

Sets the impedance for the E1 mode

Yes

 

 

 

 

A00Fh

Read T1 Volts

Returns the Vpp measurement result

—-

Peak-to-Peak

 

 

 

 

 

 

 

A013h

Set T1/E1 Receive Input

Sets the Rx input configuration for T1 and E1 modes

Yes

Configuration Options

 

 

 

 

 

 

 

A014h

Set T1/E1 Measurement

Sets T1 and E1 measurement duration

Yes

Duration

 

 

 

 

 

 

 

A015h

Set T1/E1 Data Logging

Enables/disables data logging in T1/E1 modes

Yes

 

 

 

 

A016h

Read T1/E1 dBdsx

Initiates a voltage measurement and returns the result in dBdsx

—-

 

 

 

 

A017h

Read T1/E1 Frequency

Returns the last T1/E1 frequency measurement result in Hz if available

—-

 

 

 

 

A018h

Read T1/E1 Freq Cal

Returns the current T1/E1 frequency calibration setting

—-

 

 

 

 

A019h

Set T1/E1 Frequency Cal

Sets the T1/E1 frequency calibration value

Yes

 

 

 

 

A103h

Select SPA/Power Meter

Selects a Signal Standard

Yes

Signal Standard

 

 

 

 

 

 

 

A201h

Read External Module

Returns the name of the attached external block converter module (Option 6

—-

Name

only)

 

 

 

 

 

 

A202h

Read External Module

Returns the serial number of the attached external block converter module

—-

Serial Number

(Option 6 only)

 

 

 

 

 

 

A203h

Read External Module

Returns the frequency range of the attached external block converter module

—-

Frequency Range

(Option 6 only)

 

 

 

 

 

 

A204h

Read Module Fail Counter

Returns the value of the module lock fail counter (Option 6 only)

—-

 

 

 

 

A205h

Clear Module Fail Counter

Sets the module lock fail counter to 0 (Option 6 only)

—-

 

 

 

 

A104h

Select SPA/Power Meter

Selects a channel within the range of the currently selected signal standard

Yes

Channel

 

 

 

 

 

 

 

AA30h

Trigger Sweep

Causes the Site Master to perform a sweep if it is in single sweep mode

—-

 

 

 

 

AA15h

Remote Self Test

Trigger the equivalent of a "key press" selftest.

—-

 

 

 

 

NOTES: T1/E1 commands are available with Option 50 only. Power Meter commands are available with Option 29 only.

6

Site Master PM

Page 12
Image 12
Anritsu S331D, S332D manual Site Master PM