Anritsu S331D, S332D manual Set Spectrum Analyzer Max

Models: S332D S331D

1 132
Download 132 pages 8.91 Kb
Page 10
Image 10

Control Byte

Name

Description

Watchdog

 

#

Timer

 

 

 

 

 

 

 

 

42

(2Ah)

Power Meter Offset Mode

Enables or disables Power Meter offset

Yes

 

 

 

 

 

43

(2Bh)

Power Meter Zero Mode

Enables or disables Power Meter zeroing mode

Yes

 

 

 

 

 

44

(2Ch)

Power Meter RMS

Sets Power Meter RMS Averaging.

Yes

Averaging On/Off

 

 

 

 

 

 

 

 

 

45

(2Dh)

Power Meter Center

Sets the center frequency and span frequency for the Power Meter mode

Yes

Frequency and Span

 

 

 

 

 

 

 

 

 

48

(30h)

Trigger Sweep

Starts the next sweep

—-

 

 

 

 

 

50

(32h)

Check Battery Status

Returns smart battery status

—-

 

 

 

 

 

53

(35h)

Set SPA Minimum Sweep

Sets the min sweep time for the SPA when the span is 0

Yes

Time

 

 

 

 

 

 

 

 

 

54

(36h)

Set Trigger Position

Sets the trigger position for the SPA when the span is 0

Yes

 

 

 

 

 

55

(37h)

Set Video Trigger Level

Sets the trigger level for the SPA in video trigger mode

Yes

 

 

 

 

 

64

(40h)

Auto Save Runtime Setup

Automatically save the runtime setup when exiting remote mode

Yes

 

 

 

 

 

69

(45h)

Enter Remote Mode

Enters remote mode at the end of the sweep and returns model number and

—-

firmware version

 

 

 

 

 

 

 

 

 

70

(46h)

Enter Remote Mode

Enters remote mode immediately and returns model number and firmware

—-

Immediately

version

 

 

 

 

 

 

 

 

80

(50h)

Write Custom Cable

Writes Custom Cable data to Site Master

Yes

 

 

 

 

 

81

(51h)

Recall Custom Cable

Recalls Custom Cable data from Site Master

Yes

 

 

 

 

 

82

(52h)

Write Antenna

Writes custom antenna data to the Site Master via the serial port

Yes

 

 

 

 

 

83

(53h)

Recall Antenna

Recalls custom antenna data from the Site Master via the serial port

Yes

 

 

 

 

 

84

(54h)

Set Field Strength

Sets the field strength measurement state and the antenna index

Yes

Measurement

 

 

 

 

 

 

 

 

 

85

(55h)

Set Channel Power

Sets the Channel Power measurement state and the setup parameters

Yes

 

 

 

 

 

86

(56h)

Read Channel Power

Reads the current channel power or the channel power of a stored trace

Yes

 

 

 

 

 

87

(57h)

Set ACPR

Sets the ACPR measurement state and parameters

Yes

 

 

 

 

 

88

(58h)

Read ACPR

Reads the current adjacent channel power or the adjacent channel power of a

Yes

stored trace

 

 

 

 

 

 

 

 

 

89

(59h)

Read Signal Standard

Returns the signal standard name in English

Yes

Name

 

 

 

 

 

 

 

 

 

96

(60h)

Measure OCC BW % of

Measures OCC BW with % of Power method

Yes

Power

 

 

 

 

 

 

 

 

 

97

(61h)

Measure OCC BW dB

Measures OCC BW with dB down method

Yes

Down

 

 

 

 

 

 

 

 

 

98

(62h)

Set Bias Tee Function

Set the Bias Tee function On/Off (Option 10 only)

Yes

 

 

 

 

 

99

(63h)

Set Spectrum Analyzer

Sets the Spectrum Analyzer Start and Stop frequencies

Yes

Start/Stop Frequency

 

 

 

 

 

 

 

 

 

100 (64h)

Set Spectrum Analyzer

Sets the Spectrum Analyzer center frequency and frequency span

Yes

Center Freq./Span

 

 

 

 

 

 

 

 

 

101 (65h)

Set Spectrum Analyzer

Sets the Spectrum Analyzer reference level and scale value

Yes

Scale

 

 

 

 

 

 

 

 

 

102 (66h)

Set Spectrum Analyzer

Sets position and on/off status of a Spectrum Analyzer marker

Yes

Marker

 

 

 

 

 

 

 

 

 

103 (67h)

Set Spectrum Analyzer

Sets position and on/off status of Spectrum Analyzer single limit line

Yes

Single Limit

 

 

 

 

 

 

 

 

 

105 (69h)

Set Spectrum Analyzer Max

Enables or disables the Spectrum Analyzer Max Hold feature

Yes

Hold

 

 

 

 

 

 

 

 

 

4

Site Master PM

Page 10
Image 10
Anritsu S331D, S332D manual Set Spectrum Analyzer Max