Control Byte Summary

Control Byte

Name

Description

Watchdog

 

#

Timer

 

 

 

 

 

 

 

1 (01h)

Setup System

Sets system status flags and switches

Yes

 

 

 

 

2 (02h)

Set VNA Frequency

Sets Site Master VNA frequency range

Yes

 

 

 

 

3 (03h)

Select Measurement Mode

Sets current Site Master measurement mode

Yes

 

 

 

 

4 (04h)

Set VNA Scale

Sets Site Master VNA scale values

Yes

 

 

 

 

5 (05h)

Set VNA Marker

Sets position and on/off status of Site Master markers in VNA modes

Yes

 

 

 

 

6 (06h)

Set VNA Single Limit

Sets position and on/off status of the Site Master single limit in VNA modes

Yes

 

 

 

 

7 (07h)

Set DTF Parameters

Sets Distance to Fault parameters

Yes

 

 

 

 

8 (08h)

Set Time/Date

Sets time and date of the Site Master

Yes

 

 

 

 

9 (09h)

Set Reference Number

Sets reference number (trace name) for a sweep trace

Yes

 

 

 

 

 

10

(0Ah)

Serial Port Echo On/Off

Allows synchronization of Site Master and request from computer for sweep trace

Yes

 

 

 

 

 

11

(0Bh)

VNA Single Sweep On/Off

Enables or disables single sweep operation in VNA modes

Yes

 

 

 

 

 

12

(0Ch)

Watch-dog Timer On/Off

Enables or disables the watch-dog timer

—-

 

 

 

 

 

13

(0Dh)

Sequence SM Calibration

Triggers a calibration step

Yes

 

 

 

 

 

14

(0Eh)

Set Site Master Data Points

Sets number of measurement data points for Site Master VNA modes

Yes

 

 

 

 

 

15

(0Fh)

Set SM Calibration Mode

Sets the Site Master calibration mode to OSL Cal (standard) or FlexCal

Yes

 

 

 

 

 

16

(10h)

Store Sweep Trace

Saves current trace data to EEPROM

—-

 

 

 

 

 

17

(11h)

Recall Sweep Trace

Site Master sends the sweep data associated with a trace (obsolete)

Yes

 

 

 

 

 

18

(12h)

Save System Setup

Saves system setup parameters to EEPROM

Yes

 

 

 

 

 

19

(13h)

Recall System Setup

Recalls system setup parameters from EEPROM

Yes

 

 

 

 

 

20

(14h)

Query System Status

Gets the current system settings (obsolete)

—-

 

 

 

 

 

21

(15h)

Trigger Self-Test

Triggers a self test

—-

 

 

 

 

 

22

(16h)

Read Fail Counters

Returns the values of the lock-fail and integrator counters

—-

 

 

 

 

 

24

(18h)

Query Trace Names

Returns list of all saved traces

—-

 

 

 

 

 

25

(19h)

Delete Sweep Trace

Deletes single or all stored sweep traces

Yes

 

 

 

 

 

26

(1Ah)

Upload SPA Sweep Trace

Uploads a spectrum analyzer sweep trace to Site Master (obsolete)

Yes

 

 

 

 

 

27

(1Bh)

Query Sweep Memory

Queries Site Master for percentage of memory that is available for trace storage

—-

 

 

 

 

 

28

(1Ch)

Upload VNA Sweep Trace

Uploads a Site Master VNA mode sweep trace to the Site Master (obsolete)

Yes

 

 

 

 

 

29

(1Dh)

Query System Status

Queries the Site Master for current system settings

Yes

 

 

 

 

 

30

(1Eh)

Select Printer Type

Selects printer type

Yes

 

 

 

 

 

31

(1Fh)

Select DTF Windowing

Selects DTF Windowing Methods

Yes

 

 

 

 

 

32

(20h)

Set VNA Trace Math

Selects Trace Math operation for VNA modes

Yes

 

 

 

 

 

33

(21h)

Recall Sweep Trace

Queries the Site Master for sweep trace data

Yes

 

 

 

 

 

34

(22h)

Set VNA Trace Overlay

Sets trace overlay operation and trace for VNA modes

Yes

 

 

 

 

 

35

(23h)

Set SPA A/B Trace

Defines traces “A” and “B” for SPA mode

Yes

 

 

 

 

 

36

(24h)

Upload Sweep Trace

Uploads a sweep trace to the Site Master

Yes

 

 

 

 

 

37

(25h)

Get Options

Returns an ASCII string listing installed options

—-

 

 

 

 

 

39

(27h)

Query Power Level

Returns power level at RF In in Power Meter mode

—-

 

 

 

 

 

40

(28h)

Set Power Meter Units

Sets Power Meter displaying unit

Yes

 

 

 

 

 

41

(29h)

Power Meter Relative Mode

Enables or disables Power Meter Relative Mode

Yes

 

 

 

 

 

Site Master PM

3

Page 9
Image 9
Anritsu S332D, S331D manual Control Byte Summary