Anritsu S331D, S332D manual Set T1/E1 Framing Mode Control Word A005h Option 50 only

Models: S332D S331D

1 132
Download 132 pages 8.91 Kb
Page 104
Image 104

1)255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error: Invalid error type or value

238 (EEh) Time Out Error

Set T1/E1 Framing Mode – Control Word (A005h)

(Option 50 only)

Description: Sets the Framing Mode of T1/E1 measurement.

Bytes to Follow: 1 byte

1)Framing Mode 00h: Auto

T1 Tester Only

01h: D4 SF

02h: ESF

E1 Tester Only

03h: PCM30

04h: PCM30 CRC

05h: PCM31

06h: PCM31 CRC

Site Master Returns: 1 byte

1)255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error: Invalid framing mode

238 (EEh) Time Out Error

Start and Stop T1/E1 Measurement – Control Word (A006h)

(Option 50 only)

Description: This command toggles the Run/Stop state of the T1/E1 measurement. That is, if the command is sent while the measurement is running, the command stops the measurement. If the command is sent when the measurement is stopped, the command starts the measurement.

Bytes to Follow: 0 bytes

Site Master Returns: 1 byte

1)255 (FFh) Operation Complete Byte

238 (EEh) Time Out Error

Insert Error for T1/E1 Measurement – Control Word (A007h)

(Option 50 only)

Description: This command inserts the error defined into the data flow.

Bytes to Follow: 0 bytes

Site Master Returns: 1 byte

1)255 (FFh) Operation Complete Byte

238 (EEh) Time Out Error

Get T1/E1 Pattern – Control Word (A008h)

(Option 50 only)

Description: Get the current T1/E1 pattern.

Bytes to Follow: 0 bytes

Site Master Returns: 1 byte

1)T1 Pattern

98

Site Master PM

Page 104
Image 104