Anritsu S332D, S331D manual Site Master PM 115

Models: S332D S331D

1 132
Download 132 pages 8.91 Kb
Page 121
Image 121

case ‘3’:

 

 

CommSettings.BaudRate = CBR_38400;

// rate -

38400

break;

 

 

case ‘4’:

 

 

CommSettings.BaudRate = CBR_56000;

// rate -

56000

break;

 

 

case ‘5’:

 

 

CommSettings.BaudRate = CBR_115200; // rate -

115200

break;

 

 

default:

 

 

CommSettings.BaudRate = CBR_9600;

//Default - 9600

break;

 

 

}

//disable null stripping CommSettings.fNull = FALSE;

//RTS flow control

CommSettings.fRtsControl = RTS_CONTROL_ENABLE;

//XON/XOFF in flow control CommSettings.fInX = FALSE;

//XON/XOFF out flow control CommSettings.fOutX = FALSE;

//DTR flow control type CommSettings.fDtrControl = DTR_CONTROL_ENABLE;

//number of bits/byte, 4-8 CommSettings.ByteSize = 8;

//0-4=no,odd,even,mark,space CommSettings.Parity = NOPARITY;

//0,1,2 = 1, 1.5, 2

CommSettings.StopBits = ONESTOPBIT;

/* Setting the COM State with the changed parameters

Syntax -

 

BOOL SetCommState(

 

HANDLE hFile,

// handle to communications device

LPDCB lpDCB

// pointer to device-control block structure

);

 

*/

 

PortReady = SetCommState (ComHandle, &CommSettings);

/* Setting the parameters for the timeouts.

Site Master PM

115

Page 121
Image 121