79)Pattern Sync Status (00h: In Sync, 01h: Out-of-Sync)

80)Carrier Status (00h: In Sync, 01h: Out-of-Sync)

81)Rx Alarms (bit 0: Receiving AIS, bit 1: Receiving RAI, bit 2: Receiving E1 MMF error)

82)BPV Error Count (highest byte)

83)BPV Error Count

84)BPV Error Count

85)BPV Error Count (lowest byte)

86)CRC Error Count (highest byte)

87)CRC Error Count

88)CRC Error Count

89)CRC Error Count (lowest byte)

90)Frame Error Count (highest byte)

91)Frame Error Count

92)Frame Error Count

93)Frame Error Count (lowest byte)

94)LOF Error Count (highest byte)

95)LOF Error Count

96)LOF Error Count

97)LOF Error Count (lowest byte)

98)E Bit Error Count (E1 Only) (highest byte)

99)E Bit Error Count (E1 Only)

100)E Bit Error Count (E1 Only)

101)E Bit Error Count (E1 Only) (lowest byte)

102)Errored Seconds (highest byte)

103)Errored Seconds

104)Errored Seconds

105)Errored Seconds (lowest byte)

106)Bit Count (highest byte)

107)Bit Count

108)Bit Count

109)Bit Count (lowest byte)

110)Bit Errors (highest byte)

111)Bit Errors

112)Bit Errors

113)Bit Errors (lowest byte)

114)User Defined Pattern (convert to binary for pattern) (highest byte)

115)User Defined Pattern

116)User Defined Pattern

117)User Defined Pattern (lowest byte)

118 – 125) Measurement Start Time String (ASCII string: “HH:MM:SS”)

126 – 136) Measurement Stop Time String (ASCII string: “DD:HH:MM:SS”)

137 – 147) Elapsed Time String (ASCII string: “DD:HH:MM:SS”)

148 – 155) Bit Error Rate String (ASCII string in engineering format: x.xxE-xx)

156 – 655) 100 data points with 5 bytes for each data point.

1st byte has information about Carrier Loss, Frame Loss, BPV and CRC Following 4 bytes corresponds to the Bit Error Count

Break down of the 1st byte:

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

 

 

 

 

 

 

 

 

Not Used

Not Used

Not Used

Carrier Loss

Frame Loss

BPV Error

CRC/E-bit

Any Error

Error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

Site Master PM

Page 66
Image 66
Anritsu S331D, S332D manual Bit