Read External Module Serial Number – Control Word (A202h)

(Option 6 only)

Description: Sets the serial number of the attached external converter module (Option 6).

For example, serial number 12345678 will be received as: 8,1,2,3,4,5,6,7,8,ff

Bytes to Follow: 0 bytes

Site Master Returns: 10 bytes

1)Length of Serial Number (8) 2-9) Serial Number

10)255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error: Module not attached

238 (EEh) Time Out Error

or

1)255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error: Module not attached

238 (EEh) Time Out Error

Read External Module Frequency Range – Control Word (A203h)

(Option 6 only)

Description: Sets the frequency range of the attached external converter module (Option 6). Frequency values are scaled by the scale factor value.

For example, the frequency range of the FCN4760 is as follows:

Scale factor: 10

Input Start Frequency: 4700 MHz (scaled, this number is 470 MHz)

Input End Frequency: 6000 MHz (scaled, this number is 600 MHz)

Output Start Frequency: 450 MHz (scaled, this number is 45 MHz)

Output End Frequency: 1750 MHz (scaled, this number is 600 MHz)

So the response will look like: 12,0,a,1c,3,a1,80,23,c3,46,0,2,ae,a5,40,a,6e,49,c0,ff

Bytes to Follow: 0 bytes

Site Master Returns: 20 bytes (success) or 1 byte (failure)

1)Length of Frequency Data (18) 2-3) Scale Factor (in Hz)

4-7) Input Start Frequency (scaled by Scale Factor)

8-11) Input End Frequency (scaled by Scale Factor)

12-15) Output Start Frequency (scaled by Scale Factor)

16-19) Output End Frequency (scaled by Scale Factor)

20)255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error: Module not attached

238 (EEh) Time Out Error

or

1)255 (FFh) Operation Complete Byte

224 (E0h) Parameter Error: Module not attached

238 (EEh) Time Out Error

Read Module Fail Counter – Control Word (A204h)

(Option 6 only)

Description: Returns the value of the module lock fail counter.

Bytes to Follow: 0 bytes

Site Master Returns: 2 bytes (success) or 1 byte (failure)

104

Site Master PM

Page 110
Image 110
Anritsu S331D, S332D manual Read Module Fail Counter Control Word A204h Option 6 only, Site Master PM