Echo
Packet loss concealment (PLC)
Some packet loss can be dealt with by attempting to conceal the loss by generating voice samples to take the place of the missing samples. ITU standards G.711 Annex I and the G.729 standard define methods by which packet loss concealment can be provided. Excessive packet loss cannot be disguised so, ultimately, PLC gives way to comfort noise generation (CNG) if too many packets are lost in succession.
Ramping down to silence is a typical way that PLC is performed. Loss of six consecutive packets is considered to be the maximum number of packets over which PLC can be sensibly applied.
Echo
The two main types of echo are acoustic echo and electrical echo caused by hybrid impedance mismatch. Usually, in a
Acoustic echo occurs when a talker’s voice traverses through the airpath in the acoustic environment of the receiver and feeds back to the microphone of the rereceiver’s terminal. The severity of the echo effect depends on the acoustic properties of the remote room. For example, room size and wall reflection characteristics.
Electrical echo is also a reflection effect but is due to an impedance mismatch between
The user's perception of echo increases with delay. In practice, most echo received within 30 ms is ignored by the human auditory system. However, if the level of the received echo signal is extremely high, even a couple of milliseconds delay will cause adverse perception of echo. Echo received after 30 ms will generally be perceived as an annoyance. Because of the
One strategy for dealing with echo is the deployment of echo cancellers at strategic places in phones or network equipment. Echo cancellers, which have varying amounts of memory, store incoming voice streams in digital form in a buffer and compare the received voice with the previously transmitted voice patterns stored in memory. If the patterns match, the canceller considers it an echoed signal and attempts to remove it.
Because echo cancellers are not perfect, there is a residual level of echo left even in optimal operating conditions. Echo cancellers operate properly only if the
Avaya's G350 and G700 Media Gateways, the Avaya MM760 VoIP Media Module, the Avaya TN2302AP IP Media Processor (in the G650 Media Gateways), the Avaya TN2602AP IP Media
Issue 6 January 2008 249