Greenfield deployment
Figure 38: S8700-series with G150/G250 -- large number of remote branches
Required circuit packs for S8700-series configuration
The circuit packs that are required for IP Telephony in a Communication Manager system include:
●TN2312BP IP Server Interface (IPSI) for Port Network control. For detailed information, see IP Server Interface (TN2312BP) on page 85.
●TN799DP Control LAN
●TN2302AP and/or TN2602AP Media Processors or the media flow. For detailed information, see IP Media Processor (TN2302AP, TN2602AP) on page 86.
These circuit packs can reside in the CMC1, SCC1, MCC1, or G650 Media Gateways in
The signaling connectivity path between the endpoint and the servers in the S8700 configuration is shown in Figure 41: Signaling flow on page 118.