Maintenance Commands 6-43
Octel 200/300 S.4.1PB6001901
If only one port is specified, the Octel 200/300 tries to initialize and cancel forwarding for only the port
specified. If a range is specified, the message server tries to initialize and cancel forwarding for all ports
in the range. If no port is specified, the message server tries to initialize and cancel forwarding for all
ports. If a port is successfully initialized and forwarding is canceled, it goes to the IDL state. If a port
fails to complete either the initialization or the forwarding, the status remains NDT.
For additional information about using the CUxyzcommand,refer to the System Service Mode
Commands, Courtesy Up/Courtesy Down, section.
System Status
Use the TEST STATUScommand to check the message server status for DC voltages and the
temperature. At the @ prompt, enter:
TE S Enter
If DC voltages and the temperature are within acceptable ranges the Octel 200/300 responds with:
SYSTEM STATUS TESTED OK.
If DC voltages and the temperature are out of range, the Octel 200/300 responds with the following:
ERROR DETECTED. SEE HARDWARE ERROR TABLE.
List Features
Use the LIST FEATUREScommand to list the following:
-Optional feature packages installed
-Number of installed, authorized, and used ports, mailboxes, and disk-storage hours
-Maximum number of drives, ports, and languages allowed in the message server
At the @ prompt, enter:
LF Enter