6-40 Installationand Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Use the LIST HARDWAREcommand to list the Hardware Error Table after testing the alarm or enabling
remote access. At the @ prompt, enter:
LH Enter
The Octel 200/300 prompts *** ALARM HAS BEEN GIVEN *** toindicate an alarm test was
performed. The command CLEAR HARDWAREclears this test message. At the @ prompt, enter:
CH Enter
Caution!
Youmust clear the Hardware Error Table to reset the
Octel 200/300 callout feature, or the Octel 200/300
will not attempt to call the alarm number when a true
alarm occurs. If the Table shows other errors, refer to
the System Errors and Traffic Pegs chapter, Hardware
Errors section, in this volume.
.The TE A command also closes the Alarm Relay and turns ON the Alarm.
The CHcommand reopens the Alarm Relay and turns OFF the Alarm.
Figure 6-1 shows an alarm-test flow chart.