Maintenance Commands 6-55
Octel 200/300 S.4.1PB6001901
DOUBLE INTERRUPTED RINGBACK MINIMUM TONE OFF LONG PERIOD
The shortest delay that a TONE OFF, of the long TONE OFF period, can be to qualify as a
double interrupted ringback.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a double interrupted ringback. If the TONE OFF is shorterthan this delay, the
message server assumes that it is not a double interrupted ringback.
DOUBLE INTERRUPTED RINGBACK MAXIMUM TONE OFF SHORT PERIOD
The longest delay that a TONE OFF, of the short TONE OFF period, can be to qualify as a
double interrupted ringback.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a double interrupted ringback. If the TONE OFF is longer than thisdelay, the
message server assumes that it is not a double interrupted ringback.
DOUBLE INTERRUPTED RINGBACK MINIMUM TONE OFF SHORT PERIOD
The shortest delay that a TONE OFF, of the short TONE OFF period, can be to qualify as a
double interrupted ringback.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is double interrupted ringback. If the TONE OFF is shorter than thisdelay, the
message server assumes that it is not a double interrupted ringback.
SLOW BUSY MAXIMUM TONE ON PERIOD
The longest delay that a TONE ON can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONEON is longer than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MINIMUM TONE ON PERIOD
The shortest delay that a TONE ON can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONEON is shorter than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MAXIMUM TONE OFF PERIOD
The longest delay that a TONE OFF can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONEOFF is longer than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MINIMUM TONE OFF PERIOD
The shortest delay that a TONE OFF can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONEOFF is shorter than this delay, the message
server assumes that it is not a slow-busy tone.
66
67
68
69
70
71
72