INSTALL 1-19
Octel 200/300 S.4.1PB6001901
After index 34 is answered, the port INFORMATIONTable is complete, as shown.
−−− INFORMATION TABLE 512 COMPLETE −−−
Enter the INFORMATION TABLE number to be added. (1−512)
Enter empty line when done.
Mailbox INFORMATION TableIndexes
The following indexes are applicable to the mailbox INFORMATION Table.Refer to the
Configuration volume, Information Table chapter, for details about each index.
-Index 1. If an intercept mailbox is not defined for a mailbox, the call defaults to the Intercept
Mailbox defined for the port or trunk on which the call came in.
1. INTERCEPT MAILBOX If none, uses PORT/TRUNK info.
(1−8 digits, N = NONE, empty line = NONE )
:
-Index 3. The following index appears if the Incoming Call Restriction option is installed.
3. CALL BLOCKING NUMBER (0255, 0 = NONE, empty line = NONE)
:
-Indexes 4 and 5. The following indexes appear if the Single Digit Menus are used. Index 5 is
not listed if index 4 is NONE.
4. MAX DIGIT FOR MENU (08, 0 = NONE, empty line = NONE)
:
5. PREFIX DIGIT FOR MENU (1−7 DIGITS, N = NONE, empty line = NONE)
:XX
WARNING: The following MAILBOXES must exist in the USER Table: