INSTALL 1-11
Octel 200/300 S.4.1PB6001901
Press Enter at the colon when you are finished entering mailboxes. The message server prompts
Do you wish to add more users? EnterN. The INSTALL program goes to the next
question.
If you press Enter before finishing, the Octel 200/300 asks whether you want to add more users to
the USER Table. Simply respond YES to return to the USER Table. Mailboxes may also be added
later using UPDATE.
3. SLOTS
The SLOTS Tablecontains information about each line card slot, integration card slot, and
applications card slot. The SLOTS Table allows each line card and integration card to be configured
individually. Enter the slot number and the type of card to be installed.
Different cards can be configured within a single Octel 200/300. The EntryWorks ACP card can only
be configured in slot 7 for the Octel 200 and in slot 12 for the Octel 300.
When the configuration information for a port is the same as the previous port, you only need to
enter the port extension number followed by Enter . The information for the remainder of the line is
automatically entered.
The dialog for configuring a Telemarketing Line Card (TLC) is similar to the dialog for configuring
a Line Interface Card (LIC).
.When you install a PIC card, you must configure the system clock (master clock) sync source.
Refer to the Configuration volume, Slots Table chapter, for information about the LSPTAB
Table and the master clock configuration.