Quick Reference Guide
Octel 200/300
LAN Card
Octel 200/300 S.4.1PB6001901
Command Description
Taking LAN cardout of service and returning it to service
Courtesy Down
CD x Takes the LAN card out of service without interrupting
activities in progress.
x= slot number of LAN card.
Courtesy Up
CU x Brings the LAN card back into service.
x= slot number of LAN card.
Digital Network Test
TEST LAN TEST LAN Tests all locations in the digital network.
TEST LAN x Tests a single location in the digital network;
x= the specific location name to be tested.
SNMP Test
TEST SNMP TEST SNMP Tests the mechanism of communication between the
Octel 200/300 message servers and the SNMP manager
system.
Maintenance and Troubleshooting
Diagnostic Tools
LAN CARD PING
Echo Test
CMD x PING y Lowest level “echo” test from the local LAN to the
destination message server to verify that both LAN cards
are UP,data transfer is possible, and IP addresses are
correct.
x= slot number of LAN card in servers with CPU/VCU
y= IP address of the device to which the Ethernet
packet is sent.
LAN STATUS LANSTAT Lists basic information about the current status of the LAN
— UP,DOWN, INITIALIZING.