System Errors and Traffic Pegs 8-5
Octel 200/300 S.4.1PB6001901
8.2 HARDWARE ERRORS
The Octel 200/300 logs each hardware error, along with its date, time, and type, in the Hardware Error
Table. This section explains how to read and interpret the information in the Hardware Error Table. It
also suggests some probable causes and remedies.
-The command LIST HARDWARE is used to list the Hardware Error Table. From the @ prompt, enter
LH Enter
-The command CLEAR HARDWARE is used to clear the Hardware Error Table. From the @ prompt,
enter
CH Enter
-For some hardware errors it may be necessary to translate the error bits into the error code. To
display which bits are set in a HEXadecimal number (max 16 bits), from the @ prompt, enter
BITTST x
where xis a hexadecimal number.
An example to see which bits are set in the hex number 1234:
@BITTST 1234
BIT 2 IS SET
BIT 4 IS SET
BIT 5 IS SET
BIT 9 IS SET
BIT 12ISSET
@
Hardware Error Table example and field description:
@L H
THU MM/DD 22:29:56 YYYY E1_ISDN ID:200444 S/N:200003 PBX:32
CLEARED: 08/26 11:02
TYPE SLOT CHNL PRIO DATE TIME #BAD DATA1DATA2 DATA3 DATA4
0109 00 101/2104:24 10000000100000000 00000034 00000007
0109 00 101/2104:25 1000000010000000100000034 00000007
0109 00 101/2104:25 10000000100000002 00000034 00000007
@
-TYPE. Range 1nn. Indicates which hardware assembly detected an error or failed to perform a
function. See Table 8-2.
-SLOT. Where applicable, shows slot number in which the PCAwas installed when the error was
reported.
-CHNL. Indicates the number of the failed channel.
.For Error #24 only,
CHNL 1 refers to unit 1
CHNL 2 refers to unit 2