System Errors and Traffic Pegs 8-37
Octel 200/300 S.4.1PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
68 BIC Error Dependent on value in
DATA-1.
Replace CPU card.
DATA-1 = 01 BIC read error (chip bad or missing).
DATA-1 = 02 BIC checksum error
2
DATA-2 = Computed checksum.
DATA-3 = Checksum stored in BIC.
1
69 VCU Software
port-controller
error
Error detected with
controller.
Contact your technical support center. 3
DATA-1 = VCU software logical port with error status.
DATA-2 = Currently active port-control-block for port-block 0 or 1.
DATA-3 = Port block status.
Bit 0 = Parity error
Bit 1 = Direction error
Bit 2 = Request timing error
Bit 3 = Port operation complete
70 Control Bus error
on a DSP-based
card
Error in Control Bus
I/O between CPU and
card.
Replace the DSP-based card. If error
repeats, call your technical support center.
3
DATA-1 = 03 Timeout on an ISDN request
04 Timeout on a DTIC request
05 Timeout on a DPNSS request
06 Timeout on a QSIG request
DATA-2 = Indicates the message type for which the time out occurred.
DATA-3 = User Number, if applicable.
71 High Speed Link
Monitor Error
The Digital
Networking
high-speed link is
down more than the
maximum configured
in System Parameters
267–269. An error is
logged per location.
Check remote location to see if digital
networking is up. Follow troubleshooting
guidelines in the Networking volume,
Digital Networking chapter.
3
DATA-1 = Location number for which logged
DATA-2 = Sub-type, the possible values are as follows:
1 = continuous downtime exceeded system parameter 267
2 = cumulative downtime exceeded system parameter 268
3 = Number of times down exceeded system parameter 269
DATA-3 = Unused
DATA-4 = Unused