8-18 Installationand Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
Error Codes for all DATAvalues:
00 = NO ERRORS DETECTED
01 = CHANNEL STATUSREGISTER ERROR
02 = CVSD DATAREGISTER BIT/ADDRESS ERROR
04 = A/D CONVERTER OR POWER DETECT ERROR
08 = CVSD ENCODING CIRCUIT ERROR
10 = DTMF SENDER, POWER LIMITER ERROR
20 = CVSD DECODING CIRCUIT OR OUTPUT GAIN CIRCUIT ERROR
40 = CVSD DECODING, ENCODING ERROR
80 = DTMF SENDER, DTMF DECODER ERROR, OR BAND PASS FILTER
CIRCUIT ERROR
FF = FATAL ERROR
34 Power-ON
Diagnostic Error
Selftest for integration
cards.
TE INT
LI INT
DATA-1through
DATA-4designate
errors found.
Replace integration card as indicated by
slot number.
2
DATA-1:
Bit 5: TIMER
Bit 4: NMI
Bit 3: Incorrect checksum fond in code during normal operation
Bit 2: Normal (error found during normal code operation)
Bit 1: BOOT (error found during boot process)
Bit 0: Incorrect checksum found in code during boot process
DATA-2
Bit 7: Error detected on Link 4
Bit 6: Error detected on Link 3
Bit 5: Error detected on Link 2
Bit 4: Error detected on Link 1
Bit 3: RAM error type 4
Bit 2: RAM error type 3
Bit 1: RAM error type 2
Bit 0: RAM error type 1
DATA-3 = UNDEFINED
DATA-4 = UNDEFINED