8-16 Installationand Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name PriorityRemedySource
DATA-2 =
3D = DUAL PORT RAM READ/WRITE TEST FAILED
3E = DUAL PORTRAM VERIFY TEST FAILED
3F = STATIC RAM READ/WRITE TEST FAILED
40 = STATICRAM VERIFY TEST FAILED
41 = UNEXPECTED INTERRUPT RECEIVED BY
COPROCESSOR
42 = UNEXPECTED NMI RECEIVED BY
COPROCESSOR
43 = COPROCESSOR EXECUTED A WILD JUMP
44 = TIMED OUT WAITING FOR COPROCESSOR
READY
02 = TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 1 TO
COMPLETE
03 = TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 2 TO
COMPLETE
04 = COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 1
05 = COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 2
33:Line Card
Hardware Error
Error logged by
selftest when start
LSP reply was
received with either
an error status or an
unexpected OK status
(e.g., Slot is empty or
already reported
down)
Contact your technical support center. 3
The DATA-1field specifies the type of error. DATA-2and DATA-3are data associated
with the error.
DATA-1 = REPORTED STATUS
00 = STARTLSP REPLY RECEIVED WITH EITHER AN ERROR
STATUSOR AN UNEXPECTED OK STATUS
(e.g. slot is empty or already reported down.)