Installation 4βˆ’27
PB60019βˆ’01 Octel 200/300 S.4.1
A line card installation kit is required if you are installing either line or integration cards for the
Octel 200/300.
.For more information about the installation of an integration card, refer to the appropriate chapter
in the Integration volume. For information about installing the EntryWorks ACP card, refer to the
Worksfor Serenade documentation.
Connector Blocks
Figure 4-9 shows the connector block used to addwiring for the Octel 200/300. The block is supplied in
the installation kit. The connector block has 50 separate punchdown contacts in each column, with each
column wired to an amphenol connector at the side of the block. Column A is wired to jack 1, column B
to jack 2, etc.
Mount the block to the backboard in the location that you have specified. Mounting screws are provided
when the block is ordered. Mount the block with the word β€œTOP”(embossed in the plastic, located at the
upper left side of the block) facing up (refer to Figure 4-9).