LAN Installation and Configuration 11-9
Octel 200/300 S.4.1PB6001901
LAN Status Description
UP The LAN is running. If a COURTESY DOWN is in progress, the message
COURTESY DOWN IN PROGRESS displays. When the LAN status is
UP the highspeed link status is given for each highspeed digital
location as follows:
-LOCATION The location name.
-STATUS The status of the link to this location, which is either
UP or DOWN.
-LANPPRTCL The Digital Networking Protocol level of the other
system. This entry allows compatibility with future
releases. It does not relate to analog protocol
numbering.
-OTHER Can be one of the following:
HNDSHAKE, waiting for startup handshake reply;
OEM-FAIL, cannot establish connection, OEM
mismatch
INITIALIZING TheLAN is in the initialization process. The current status of the initializa-
tion process is given from among the following:
-WAITING FOR LAN REBUILD TO COMPLETE
-WAITING FOR LAN TO START
-WAITING FOR LAN INFO FROM VCU
-STARTING HIGHSPEED CONNECTIONS
DOWN Communication with the LAN adapter has stopped and no LAN activity is
possible. The reason, if known, is given. The following are possible
reasons:
-System does not have the Digital Networking feature
-ACOURTESYDOWN is in progress
-LAN SYSTEM PARAMETER NOT ENABLED
-LAN BOARD NOT CONFIGURED IN SLOTS TABLE
At any time during the LAN STATUSlisting, you can press Escape to terminate the listing within a line
or two.