Octel 200/300 S.4.1PB60019āˆ’01

System Parameters

The following System Parameters are particular to the requirements for the UK. The installation engineer
must verify that these parameters have the following assignments:
Number System Parameter Name Value
68 NET:REMOTE DELIVERY ATTEMPTLIMIT 20
69 NET:REMOTE DELAYBEFORE RETRY (MINUTES) 10
.Delays in dialing strings (D character) between the PABXaccess code and the rest of the digits
must be between 3.5 and 8 seconds. Set D character timing in System Parameter 28 ā€” ā€œDā€
CHARACTER DELAY TIME.

INFORMATION TableIndices

The following INFORMATIONTable indices are particular to the requirements for the UK. The installation
engineer must verify that these indices have the following assignments:
Number Information TableIndex Name Value
15 OFFSITE SPEAK 4
16 OFFSITE SPEAK DELAY 5
The values for INFORMATIONTable Indices 15 and 16 must be set so that the total offhook time is less
than 60 seconds. The above values meet that specification TIMES.