Black Box Remote Emulator Card, 5250 manual Cause: SDLC encoding not set properly

Models: 5250 Remote Emulator Card

1 156
Download 156 pages 50.81 Kb
Page 80
Image 80
Cause: SDLC encoding not set properly.

5250 REMOTE EMULATOR CARD

Action: Contact the system operator; he or she might need to IPL the host. Make sure the host/modem cable is attached to the emulator. If you can’t find the problem on the premises at either end, have the telephone company check the line.

Cause: SDLC encoding not set properly.

Action: The host’s and emulator’s encoding settings must match: either both NRZ or both NRZI. If you’re unsure what the host’s setting is, change this setting on the emulator (see Section 6.2.4) and try to bring it on line again.

Cause: Either host or Card is configured incorrectly.

Action: Make sure the host is configured for the emulator, that the emulator address is correct at the host, and that the host configuration and the local configuration match.

Cause: Modem is not the proper type or is not strapped properly.

Action: Verify that both modems are of the proper type for the network. Make sure the modems can communicate at the chosen line speed. Check that the modem is “strapped” for the network type (half- or full-duplex, etc.). Perform loopback or end-to-end tests to make sure host-site and emulator-site modems can communicate with each other.

Cause: Host not varied on or subsystem not started.

Action: Vary on the host as described in Section 7.1. Some hosts require the line, device(s), and subsystem to be varied on before the host can communicate. Make sure the subsystem is started.

After you connect the two modems, or when the Card is directly connected to a host without modems, DCD and DSR should be lit.

Once the host starts polling, the RX LED should flash. If everything is configured properly, RTS should light, followed immediately by CTS, followed immediately by TX.

If DCD and/or DSR are not lit, eiter there is a problem with the configuration of the modem or CSU/DSU, or the cable between the emulator and the modem or CSU/DSU is defective.

79

Page 80
Image 80