2-38
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-05
Note The thresholds for the following fields are set based upon the number of error message which c an occur
in one second. The value can be from 1 to 65,535.
portSymbolErrThresh
The threshold for the number of times a 8B10B encoding violation, or a disparity violat ion was
detected on the port.
portLinkErrRecvThresh
The threshold for the number of times the link error recovery process happened successfully on the
port.
portLinkDownedThresh
The threshold for the number of times the link error recovery process failed on the port.
portRecvErrThresh
The threshold for the number of errors received on the port.
portRecvRemPhysErrThresh
The threshold for the number of remote physical errors received on the port.
portXmitDiscardThresh
The threshold for the number of transmit discards rec eived on the port.
portPKeyViolInThresh
The threshold for the number of times PKey inbound was invalid on the port.
portPKeyViolOutThresh
The threshold for the number of times PKey outbound was invalid on the port.
portRawViolInThresh
The threshold for the number of times a raw inbound pa cket was discarded by the port.
portRawViolOutThresh
The threshold for the number of times a raw outbound p acket was discarded by the port.
portLocalLinkIntegThresh
The threshold for the number of local link integrity errors on the port.
portExcBufferOverrunThresh
The threshold for the number of excessive buffer overrun errors on the port.
Time Service
The System Time Information screen allows the user to set the system time using either network time
protocol (NTP) or manual overrides.