Clarity Visual Systems

Environmental

Specification

Units

Maximum

Minimum

Typical

Notes

Temperature (operating)

Deg. C

35

0

 

All performance

 

 

 

 

 

specifications are

 

 

 

 

 

maintained within this

 

 

 

 

 

temperature range

Non operating

Deg. C

60

-10

 

 

 

 

 

 

 

 

Shock

G’s

10

 

 

 

 

 

 

 

 

 

Shipping

 

 

 

 

ASTM Qualified

 

 

 

 

 

 

Altitude

Feet

10,000

 

 

 

 

 

 

 

 

 

Humidity

% R.H.

80

20

 

40° C Non-condensing

 

 

 

 

 

 

Picture Control

Specification

Units

Maximum

Minimum

Typical

Notes

User controls

 

 

 

 

 

Input gain

 

2x

0.5x

 

 

RGB Gain

# of

 

 

+64

For white color balance.

 

levels

 

 

 

Each level individually

 

 

 

 

 

gamma corrected.

Position

# of

 

 

±64

Both H and V

 

pixels

 

 

 

 

Fan timeout in standby

Seconds

 

 

30

 

 

 

 

 

 

 

Lamp restart time

Seconds

 

 

30

 

 

 

 

 

 

 

Lamp start incremental

Seconds

 

 

Monitor ID

Sequential start to avoid

delay

 

 

 

# x2

power sag

IR remote

 

 

 

Infrared

Allows control over all user

 

 

 

 

 

adjustments

Serial I/O

 

 

 

 

RS-232 control for all user

 

 

 

 

 

adjustments

108September 1999