Clarity Visual Systems
September 1999
108
Environmental
Specification Units Maximum Minimum Typical Notes
Temperature (operating) Deg. C 35 0 All performance
specifications are
maintained within this
temperature range
Non operating Deg. C 60 -10
Shock G’s 10
Shipping ASTM Qualified
Altitude Feet 10,000
Humidity % R.H. 80 20 40°C Non-condensing
Picture Control
Specification Units Maximum Minimum Typical Notes
User controls
Input gain 2x 0.5x
RGB Gain # of
levels +64 For white color balance.
Each level individually
gamma corrected.
Position # of
pixels ±64 Both H and V
Fan timeout in standby Seconds 30
Lamp restart time Seconds 30
Lamp start incremental
delay Seconds Monitor ID
# x2 Sequential start to avoid
power sag
IR remote Infrared Allows control over all user
adjustments
Serial I/O RS-232 control for all user
adjustments