Clarity Visual Systems

Image Problems

 

 

Follow these steps in order. Check

Symptom

 

the operation of the display after each step.

 

 

 

Image is dim

1.

Verify that the input signal is good

 

2.

Adjust the Black Level via the menu while displaying a black

 

 

video image and the White Level while displaying a white video

 

 

image

 

3.

Set each of the colors in the Color Balance menu to 31 (white)

 

 

and 7 (gray)

 

 

 

 

 

 

Color problem

1.

Verify that the correct source is selected in the Source Select

Screen is all black or all

2.

menu

white

Make sure that all of the video cables are plugged into the source

 

and the display. Verify that the cables are good.

Image has an abnormally

 

3.

If the image has a strong green hue, verify that the input signal is

strong hue of a single color

 

not setup as sync-on-green. If it is, you will need to select the

 

 

Sync on Green option in the Source select menu.

 

4.

Verify that Curtain in the menu is off by pressing the Curtain

 

 

button on the remote. There should be no X.

 

5.

Adjust the White Level and Black Level in the menu

 

6.

Verify that the Test Patterns in the Misc Control menu are set to

 

 

Off.

 

7.

Contact your service provider

 

 

 

 

 

 

Displayed image is too small or

1.

If the source is a computer source, Select Source again and

too large

 

choose Auto, instead of manually selecting the mode.

 

2.

Make sure that the image is positioned correctly on the screen

 

 

using the Position function in the menu.

 

3.

Check Ultra-Thin Mullion screens. Adjusting the screen way in or

 

 

way out has an effect on image size.

 

4.

Adjust optical engine mount using internal cyan test pattern.

 

5.

Use the zoom feature to scale the image.

 

6.

Contact your service provider.

 

 

 

 

 

 

Active area of the image is not

1.

Adjust image position using the Position function in the menu.

fully on the screen

2.

Adjust lens screws LS1 and LS2 using internal cyan test pattern.

 

3.

Use the zoom feature to scale the image.

 

4.

Contact your service provider

 

 

 

76September 1999

Page 84
Image 84
Clarity WN=5230-S manual Image Problems, Follow these steps in order. Check