Clarity Visual Systems

Operation

After the displays are installed, use these procedures:

Step 1 - Power-On

Step 2 - Adjust the Input Signal Settings

Step 3 - Adjust the Colors

Step 4 - Save the Settings

Step 1 – Power-On

1. Turn the main power

The Standby LED flashes, indicating the power up cycle

 

switch on the power

has begun. Wait approximately 30 seconds until the

 

supply to the ON

Standby LED is on and not flashing.

 

position

 

 

 

 

2.

Press the remote

You will hear a ‘beep.” The lamp will come on, but it will

 

control ON button to

require a few minutes to fully warm up. There is a built-in

 

power up each Display

delay from when you press the remote’s ON button to

 

 

when the lamp starts to ignite. The extent of the delay

 

 

depends on the position of the Unit switch on the rear

 

 

panel.

 

 

GROUP ID numbers are 0-9 and A-F for a total of 16

 

 

different settings. Each number is equal to that number

 

 

times 16. A setting of 3 is equal to 48.

 

 

UNIT ID numbers are 0-9 and A-F for a total of 16

 

 

different settings. Each number is equal to that number

 

 

times one. A setting of C equals 12.

 

 

The Monitor ID number is the combination of the Group ID

 

 

plus the Unit ID. A Group ID number of 2 and a Unit ID

 

 

number of 5 equals a Monitor ID of 37 decimal, 25

 

 

hexadecimal.

 

 

The delay time between an “on” command to the display

 

 

and the ignition of the lamp is approximately 1 seconds

 

 

times the Unit ID number.

 

 

 