Emerson PMPPC7448 user manual Monitor, Command-Linefeatures, Section

Models: PMPPC7448

1 136
Download 136 pages 56.22 Kb
Page 103
Image 103
Monitor

Section 11COMMAND-LINE FEATURES

Manual backgroundManual backgroundManual backgroundManual backgroundMonitor Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

The PmPPC7448 monitor is based on the Universal Boot (U-Boot) program, available under the GNU General Public License (GPL). For instructions on how to obtain the source code for this GPL program, please visit http://www.emersonembeddedcomputing.com, send an e- mail to support@artesyncp.com, or call Emerson at 1-800-327-1251.

This chapter describes the monitor’s basic features, operation, and configuration sequences. This chapter also serves as a reference for the monitor commands and func- tions.

COMMAND-LINE FEATURES

The PmPPC7448 monitor uses a command-line interface with the following features:

Auto-Repeat:After entering a command, you can re-execute it simply by pressing the ENTER or RETURN key.

TFTP Boot: You can use the TFTP protocol to load application images via Ethernet into the

PmPPC7448’s memory.

Auto-Boot:You can store specific boot commands in the environment to be executed automatically after reset.

Flash Programming: You can write application images into Flash via the U-Boot command line. One megabyte at the base of Flash is reserved for the monitor.

At power-up or after a reset, the monitor runs diagnostics and reports the results in the start-up display, see Fig. 11-1. During the power-up sequence, the monitor configures the board according to the environment variables (see “Environment Variables” on

page 11-22)and settings in the Board Configuration registers (see “Board Configuration Registers” on page 7-6). If the configuration indicates that autoboot is enabled, the moni- tor attempts to load the application from the specified device. If the monitor is not config- ured for autoboot or a failure occurs during power-up, the monitor enters normal command-line mode.

10006757-02

PmPPC7448 User’s Manual