3. Web Control

3.6 Alert Settings

Displays and congures failure & alert settings.

Item

Description

 

 

Cover Error

The lamp cover has not been properly xed.

Fan Error

The cooling fan is not operating.

Lamp Error

The lamp does not light, and there is a possibility that interior

portion has become heated.

 

 

 

Temp Error

There is a possibility that the interior portion has become

heated.

 

 

 

Lens Door Error

The lens door is not opened or closed properly.

Air Flow Error

The internal temperature is rising.

Cold Error

There is a possibility that the interior portion has become

overcooled.

 

 

 

Filter Error

Filter time over.

 

Other Error

Other error.

 

If displaying this error, please contact your dealer.

 

Schedule Execution

Schedule Execution error. (

55)

Error

 

 

Lamp Time Alarm

Lamp time over Alarm Time setting.

Filter Time Alarm

Filter time over Alarm Time setting.

Transition Detector

Transition Detector Alarm. (

SECURITY menu in the

Alarm

User’s Manual – Operating Guide)

 

When the projector is supplied with the power, it works as

 

below.

 

Cold Start

• If the STANDBY MODE is set to the NORMAL:the projector's

power status changes from “OFF” to “Standby state”.

 

• If the STANDBY MODE is set to the SAVING:the projector's power

 

status changes from “Standby state” to “ON (lamp is turned on)”.

 

( SETUP menu in the User’s Manual – Operating Guide)

Authentication Failure

The SNMP access is detected from the invalid SNMP community.